Date: 5/12/2009 | Time: | Report ID: saddlewood051209 |
Property: 600 Ocean Lakes Drive Virginia Beach VA 23454 |
Customer: Saddlewood Condominiums |
Real Estate Professional: |
Type of building: Multi-family, Condominium | Age Of Buildings: Over 20 years | Weather: Clear |
The following key defines the comment descriptions represented in this report. Any recommendations by the inspector to repair or replace indicates an item that should be further evaluated and corrected as needed by a qualified contractor.
Inspected (IN) = This item was inspected. If no other comments were made then it appeared sound and functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= This item was not inspected. No representations of whether or not it is in satisfactory condition. Reasons for not inspecting will be noted..
Not Present (NA) = There are no exterior stairs, balcony or landings on this unit.
Balcony & Stairs (B&S) = This unit contains both a balcony and staircase.
Two Balcony's (2B) = This unit contains 2 balcony's.
Repair or Replace (RR) = Problems where observed that will require repairs or replacement. These will be indicated with a Red Flag
Note: The first photo under each condo unit shows the unit number for reference only. Units where no problems where found may or may not have a unit number reference photo.
Scope of inspection - This condominium inspection is a partial inspection and is limited to the exterior appurtances, specifically the stairs, balcony's and landings. Final Analysis Home Inspections makes no representation as to the condition of any other areas.
Remedies - Final analysis Home Inspections does not provide contracting services, repairs, or instructions on how to fix problems. It is recommended that licensed, qualified contractors be consulted for further evaluation repairs.
Depth of inspection - Though there are questionable areas regarding the original architecture and structural design of these porch and balcony structures, it is beyond the scope and purpose of this inspection to evaluate design deficiencies. This inspection is limited to only those defects, wear, deterioration and safety concerns that are within the confines of the original, pre-existing designs.
Disputes - If you feel an item has been reported in error, please submit this in writing at Final-Analysis.com . Be sure to include description of complaint, your name, contact number and address.
Condo units
|
1.0 | Unit 1601 Comments: Not applicable - No stairs or balcony |
1.1 | Unit 1603 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Observed loose, movable or detached hand rail at stairs. (Picture 3) Repair, replace and secure as needed to prevent movement. | |||
(3) Staircase framing is unstable - Observed lateral movement and deflection of the staircase. (Picture 4) Tighten and add fasteners where needed. Consider adding vertical support
post midway below staircase. | |||
(4) Stair treads are loose, lifting, damaged and can be unsafe. (Picture 5) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety. |
1.2 | Unit 1605 Comments: Not applicable - No stairs or balcony |
1.3 | Unit 1607 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 1) Repair or replace as needed in a manner that with restore stability,
function, safety and conform to original design. | |||
(2) Stair treads are loose, lifting, damaged and can be unsafe.(Picture 1) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety. | |||
(3) Floor boards are loose, warped, lifting or otherwise damaged at the stair landing. (Picture 2) repair, replace and fasten properly all floor boards where needed so that all are
level, flat, secure and conform to original design. |
1.4 | Unit 1609 Comments: Not applicable - No stairs or balcony |
1.5 | Unit 1611 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Pickets are Loose, weathered, or cracked at Balcony. Repair or replace as needed using the proper fasteners.(Picture 2) |
1.6 | Unit 1613 Comments: Not applicable - No stairs or balcony |
1.7 | Unit 1615 Comments: Inspected, This unit contains both balcony & stairs | ||
(1) Stair treads are loose, lifting, damaged and can be unsafe.(Picture 2) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety. | |||
(2) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the landing. (Picture 3) These conditions are unsafe and can lead to detachment and
cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment. |
Condo units
|
2.0 | Unit 1617 Comments: Not applicable - No stairs or balcony |
2.1 | Unit 1619 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | |
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. The balcony framing and attachments do not appear to be sufficiently designed
to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | ||
(2) Balcony structure is weathered, worn and weakened from exposure, age and deterioration. Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design. | ||
(3) Floor boards are loose, warped, lifting or otherwise damaged at the balcony. repair, replace and fasten properly all floor boards where needed so that all are level, flat, secure and conform to original design. |
2.2 | Unit 1621 Comments: Not applicable - No stairs or balcony |
2.3 | Unit 1623 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
2.4 | Unit 1625 Comments: Not applicable - No stairs or balcony |
2.5 | Unit 1627 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
2.6 | Unit 1629 Comments: Not applicable - No stairs or balcony |
2.7 | Unit 1631 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Flashing is missing where staircase is attached to structure. (Picture 2) Flashing is recommended to prevent water intrusion into the wall. |
Condo units
|
3.0 | Unit 1633 Comments: Not applicable - No stairs or balcony |
3.1 | Unit 1635 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2)The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
3.2 | Unit 1637 Comments: Not applicable - No stairs or balcony |
3.3 | Unit 1639 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2)The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
3.4 | Unit 1641 Comments: Not applicable - No stairs or balcony |
3.5 | Unit 1643 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
3.6 | Unit 1645 Comments: Not applicable - No stairs or balcony |
3.7 | Unit 1647 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2)The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Pickets are Loose, weathered, or cracked at Balcony. Repair or replace as needed using the proper fasteners.(Picture 3) | |||
(3) Stair risers are over cut and weakened at treads. Recommend sistering with riser reinforcements attached below steps. (Picture 4) |
Condo units
|
4.0 | Unit 1649 Comments: Not applicable - No stairs or balcony |
4.1 | Unit 1651 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Pickets are Loose, poorly fastened and detached at stairs.(Picture 2) Repair or replace as needed using the proper fasteners. |
4.2 | Unit 1653 Comments: Not applicable - No stairs or balcony |
4.3 | Unit 1655 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
Balcony and steps have been painted |
4.4 | Unit 1657 Comments: Not applicable - No stairs or balcony |
4.5 | Unit 1659 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Balcony structure is weathered, worn and weakened from exposure, age and deterioration.(Picture 3) Repair or replace as needed in a manner that with restore stability,
function, safety and conform to original design. | |||
(3) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design. |
4.6 | Unit 1661 Comments: Not applicable - No stairs or balcony |
4.7 | Unit 1663 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | |
(1) | ||
(2) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
Condo units
|
5.0 | Unit 1665 Comments: Not applicable - No stairs or balcony | |
5.1 | Unit 1667 Comments: Not applicable - No stairs or balcony | |
5.2 | Unit 1669 Comments: Not applicable - No stairs or balcony | |
5.3 | Unit 1671 Comments: Not applicable - No stairs or balcony | |
5.4 | Unit 1673 Comments: Not applicable - No stairs or balcony | |
5.5 | Unit 1675 Comments: Not applicable - No stairs or balcony | |
5.6 | Unit 1677 Comments: Not applicable - No stairs or balcony | |
5.7 | Unit 1679 Comments: Not applicable - No stairs or balcony | |
Condo units
|
6.0 | Unit 1681 Comments: Not applicable - No stairs or balcony | |
6.1 | Unit 1683 Comments: Not applicable - No stairs or balcony | |
6.2 | Unit 1685 Comments: Not applicable - No stairs or balcony | |
6.3 | Unit 1687 Comments: Not applicable - No stairs or balcony | |
6.4 | Unit 1689 Comments: Not applicable - No stairs or balcony | |
6.5 | Unit 1691 Comments: Not applicable - No stairs or balcony | |
6.6 | Unit 1693 Comments: Not applicable - No stairs or balcony | |
6.7 | Unit 1695 Comments: Not applicable - No stairs or balcony | |
Condo units
|
7.0 | Unit 1697 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Flashing is missing where balcony is attached to structure. (Picture 2) Flash recommended to prevent water intrusion into the wall. |
7.1 | Unit 1701 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
7.2 | Unit 1705 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
7.3 | Unit 1711 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
(1) Balcony is sagged - left balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. Pickets are Loose, weathered, or cracked at Left Balcony. Repair or replace as needed using the proper fasteners.(Picture 2) | |||
(2) Balcony is sagged - Right balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 3) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. Pickets are Loose, weathered, or cracked at Right Balcony. Repair or replace as needed using the proper fasteners. (Picture 3) |
Condo units
|
8.0 | Unit 1713 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
8.1 | Unit 1719 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
8.2 | Unit 1721 Comments: This unit contains 2 balcony's, This unit is satisfactory |
8.3 | Unit 1727 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||||
Balcony's are sagged - Left and Right balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2-5) The balcony framing and attachments do not
appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony's should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
Condo units
|
9.0 | Unit 1729 Comments: Not applicable - No stairs or balcony | |
9.1 | Unit 1731 Comments: Not applicable - No stairs or balcony | |
9.2 | Unit 1733 Comments: Not applicable - No stairs or balcony | |
9.3 | Unit 1735 Comments: Not applicable - No stairs or balcony | |
9.4 | Unit 1737 Comments: Not applicable - No stairs or balcony | |
9.5 | Unit 1739 Comments: Not applicable - No stairs or balcony | |
9.6 | Unit 1741 Comments: Not applicable - No stairs or balcony | |
9.7 | Unit 1743 Comments: Not applicable - No stairs or balcony | |
Condo units
|
10.0 | Unit 1745 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Balcony rails warped - Both left and right balcony 1x4 cap rails are warped and lifting. (Pictures 2 and 3) Repair or replaced as needed and attach securely using proper fasteners.
Note: other balcony's use 2x4's for cap rails which are less likely to warp. |
10.1 | Unit 1747 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
10.2 | Unit 1749 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
10.3 | Unit 1751 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
Condo units
|
11.0 | Unit 1753 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
11.1 | Unit 1755 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3) The balcony framing and attachments do not appear to
be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Both balcony structures are weathered, worn and weakened from exposure, age and deterioration. (Pictures 2 and 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
11.2 | Unit 1757 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
11.3 | Unit 1759 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
Condo units
|
12.0 | Unit 1761 Comments: Not applicable - No stairs or balcony | |
12.1 | Unit 1763 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2)The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Pickets are Loose, weathered, or cracked at Stairs. Repair or replace as needed using the proper fasteners. (Picture 3) |
12.2 | Unit 1765 Comments: Not applicable - No stairs or balcony | |
12.3 | Unit 1767 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Staircase frame is loose, separating, or poorly secured where the stair case attaches to the bottom landing. (Picture 2) These conditions are unsafe and can lead to detachment
and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment. |
12.4 | Unit 1769 Comments: Not applicable - No stairs or balcony |
12.5 | Unit 1771 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | |
Flashing is missing where staircase is attached to structure.(Picture 1) Flash as needed to prevent water intrusion into the wall. |
12.6 | Unit 1773 Comments: Not applicable - No stairs or balcony | |
12.7 | Unit 1775 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Staircase frame is loose, separating, or poorly secured where the stair case attaches to the lower landing. (Picture 2) These conditions are unsafe and can lead to detachment
and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment. |
Condo units
|
13.0 | Unit 615 Comments: Not applicable - No stairs or balcony | |
13.1 | Unit 617 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
13.2 | Unit 619 Comments: Not applicable - No stairs or balcony | |
13.3 | Unit 621 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
13.4 | Unit 1742 Comments: Not applicable - No stairs or balcony | |
13.5 | Unit 1744 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the landing. (Picture 2) These conditions are unsafe and can lead to detachment and
cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment. | |||
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 3) Repair or replace as needed in a manner that with restore stability,
function, safety and conform to original design. |
13.6 | Unit 1746 Comments: Not applicable - No stairs or balcony | |
13.7 | Unit 1748 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | |
(1) Observed loose, movable or detached hand rail at stairs. Repair, replace and secure as needed to prevent movement. | ||
(2) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the landing. These conditions are unsafe and can lead to detachment and cause injury.
Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment. |
Condo units
|
14.0 | Unit 623 Comments: Not applicable - No stairs or balcony | |
14.1 | Unit 625 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | |||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | ||||
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Pictures 3 - 5) Repair or replace as needed in a manner that with restore
stability, function, safety and conform to original design. |
14.2 | Unit 627 Comments: Not applicable - No stairs or balcony | |
14.3 | Unit 629 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Observed loose, movable or detached hand rail at stairs. (Picture 2) Repair, replace and secure as needed to prevent movement. | |||
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 3) Repair or replace as needed in a manner that with restore stability,
function, safety and conform to original design. |
14.4 | Unit 1710 Comments: Not applicable - No stairs or balcony | |
14.5 | Unit 1712 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
14.6 | Unit 1714 Comments: Not applicable - No stairs or balcony | |
14.7 | Unit 1716 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
Condo units
|
15.0 | Unit 631 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Right and left balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge.(Pictures 2 and 3)The balcony framing and attachments do
not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
15.1 | Unit 633 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Both balcony structures are weathered, worn and weakened from exposure, age and deterioration. (Pictures 2 and 3) Repair or replace as needed in a manner that with
restore stability, function, safety and conform to original design. |
15.2 | Unit 1772 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
15.3 | Unit 1774 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
Condo units
|
16.0 | Unit 651 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Left balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
16.1 | Unit 653 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
16.2 | Unit 1666 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
16.3 | Unit 1668 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Left balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. Cap rails warped lifting at both balcony's. (Picture 1) Repair or replace as needed using proper materials and fasteners. |
Condo units
|
17.0 | Unit 643 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not
appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
17.1 | Unit 645 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Right balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
17.2 | Unit 647 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Left and Right balcony's are sagged - balcony's is noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3)The balcony framing and attachments do
not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
17.3 | Unit 649 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Right balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
Condo units
|
18.0 | Unit 635 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
18.1 | Unit 637 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
18.2 | Unit 639 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Warped and lifting cap rails observed at both balcony's. (Pictures 2 and 3) Repair or replace as needed using proper materials and fasteners.
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern. At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
18.3 | Unit 641 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2 and 3)The balcony framing and attachments do
not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
Condo units
|
19.0 | Unit 600 Comments: Not applicable - No stairs or balcony | |
19.1 | Unit 602 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Observed loose, movable or detached hand rail at stairs. Repair, replace and secure as needed to prevent movement. | |||
(3) Pickets are Loose, weathered, or cracked at Balcony. (Picture 2) Repair or replace as needed using the proper fasteners. | |||
(4) Stair treads are loose, lifting, damaged and can be unsafe. (Picture 3) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety. |
19.2 | Unit 604 Comments: Not applicable - No stairs or balcony | |
19.3 | Unit 606 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
19.4 | Unit 608 Comments: Not applicable - No stairs or balcony | |
19.5 | Unit 610 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
19.6 | Unit 612 Comments: Not applicable - No stairs or balcony | |
19.7 | Unit 614 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
Condo units
|
20.0 | Unit 616 Comments: Not applicable - No stairs or balcony | |
20.1 | Unit 618 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Staircase framing is unstable - Observed lateral movement and deflection of the staircase.(Picture 3) Tighten and add fasteners where needed. Consider adding vertical support post
midway below staircase. | |||
(3) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 4) Repair or replace as needed in a manner that with restore stability,
function, safety and conform to original design. |
20.2 | Unit 620 Comments: Not applicable - No stairs or balcony | |
20.3 | Unit 622 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
20.4 | Unit 624 Comments: Not applicable - No stairs or balcony |
20.5 | Unit 626 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||||
(1) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Pictures 2-4) Repair or replace as needed in a manner that with restore
stability, function, safety and conform to original design. | |||||
(2) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the upper landing.(Picture 4) These conditions are unsafe and can lead to detachment
and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment. |
20.6 | Unit 628 Comments: Not applicable - No stairs or balcony | |
20.7 | Unit 630 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 3) Repair or replace as needed in a manner that with restore stability,
function, safety and conform to original design. |
Condo units
|
21.0 | Unit 632 Comments: Not applicable - No stairs or balcony | |
21.1 | Unit 634 Comments: Not applicable - No stairs or balcony | |
21.2 | Unit 636 Comments: Not applicable - No stairs or balcony | |
21.3 | Unit 638 Comments: Not applicable - No stairs or balcony | |
21.4 | Unit 640 Comments: Not applicable - No stairs or balcony | |
21.5 | Unit 642 Comments: Not applicable - No stairs or balcony | |
21.6 | Unit 644 Comments: Not applicable - No stairs or balcony | |
21.7 | Unit 646 Comments: Not applicable - No stairs or balcony | |
Condo units
|
22.0 | Unit 648 Comments: Not applicable - No stairs or balcony | |
22.1 | Unit 650 Comments: Not applicable - No stairs or balcony | |
22.2 | Unit 652 Comments: Not applicable - No stairs or balcony | |
22.3 | Unit 654 Comments: Not applicable - No stairs or balcony | |
22.4 | Unit 1601 Comments: Not applicable - No stairs or balcony | |
22.5 | Unit 1603 Comments: Not applicable - No stairs or balcony | |
22.6 | Unit 1605 Comments: Not applicable - No stairs or balcony | |
22.7 | Unit 1607 Comments: Not applicable - No stairs or balcony | |
Condo units
|
23.0 | Unit 656 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
RIGHT Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
23.1 | Unit 658 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
23.2 | Unit 1600 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
(1) Left and Right Balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2 and 3) The balcony framing and attachments
do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | ||||
(2) LEFT Balcony structure is weathered, worn and weakened from exposure, age and deterioration. Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design. | ||||
(3) Pickets are Loose, weathered, or cracked at LEFT Balcony. Repair or replace as needed using the proper fasteners. |
23.3 | Unit 1602 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
Condo units
|
24.0 | Unit 660 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2 and 3) The balcony framing and attachments
do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
24.1 | Unit 662 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
24.2 | Unit 664 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
24.3 | Unit 666 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||||
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge.(Picture 2-4) The balcony framing and attachments do not
appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
Condo units
|
25.0 | Unit 668 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
25.1 | Unit 670 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | ||
Left and right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge.(Pictures 1 and 2) The balcony framing and attachments
do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. Right balcony cap rail is warped, loose and lifting. repair or replace as needed.(Picture 2) |
25.2 | Unit 672 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
25.3 | Unit 674 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
Condo units
|
26.0 | Unit 676 Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory | |
26.1 | Unit 678 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge or are un-level left to right. (Pictures 2-3) The balcony
framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
26.2 | Unit 680 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |
Left balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 1) The balcony framing and attachments do not appear to be
sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. |
26.3 | Unit 682 Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's | |||
Left and Right balcony's are sagged - Both balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3) The balcony framing and
attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. Warped, Lifting cap rail's - Both 1x4 cap rails on balcony's are warped and lifting. (Pictures 2 and 3) Repair or replace as needed using the correct fasteners. Note: other balcony's are using 2x4's which are less likely to warp. |
Condo units
|
27.0 | Unit 1600 Comments: Not applicable - No stairs or balcony | |
27.1 | Unit 1602 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
27.2 | Unit 1604 Comments: Not applicable - No stairs or balcony | |
27.3 | Unit 1606 Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory | |
27.4 | Unit 1608 Comments: Not applicable - No stairs or balcony | |
27.5 | Unit 1610 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | ||
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently
designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.
At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed. Balcony structure is also weathered, worn and weakened from exposure, age and deterioration. (Picture 2) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design. Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design. | |||
(2) Balcony cap rail is loose warped, lifting. (Picture 3) Repair or replace as needed using proper materials and fasteners. Note: other balcony's use 2x4's which are less likely to fail. | |||
(3) Fasteners are loose, improper and failing at stair rails and post supports. (Pictures 4 and 5) Repair, Replace and reinforce as needed using proper fastening. . |
27.6 | Unit 1612 Comments: Not applicable - No stairs or balcony | |
27.7 | Unit 1614 Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs | |||
Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Pictures 2 and 3) Repair or replace as needed in a manner that with restore
stability, function, safety and conform to original design. |