Commercial Property Report     

 

" We see what's missing "

Final Analysis Property Inspections

Prepared exclusively for

Saddlewood Condominiums

600 Ocean Lakes Drive
Virginia Beach VA 23454

This condominium association was concerned about the appearance and safety of the aging balcony's and wood stairs on the exterior of all 192 residential units.  Being budget conscious, the wanted to avoid inflated or unrealistic repair estimates from contractors.  Armed with the knowledge and facts of an unbiased inspection, they where able to determine exactly what repairs where needed. With this knowledge, they where able make fair recommendations to the owners who could also use the report findings as an accurate work list to provide to contractors.

Report ID: saddlewood051209

Inspection Date: 5/12/2009
Inspected By: Dan Rogers

www.final-analysis.com

757.495.2300

Top Table of Contents Bottom

 

Table of Contents


 

Date: 5/12/2009 Time: Report ID: saddlewood051209
Property:
600 Ocean Lakes Drive
Virginia Beach VA 23454
Customer:
Saddlewood Condominiums
Real Estate Professional:

Type of building:
Multi-family, Condominium

Age Of Buildings:
Over 20 years

Weather:
Clear

Inspections of Balcony, Exterior staircases and Stair landings.

Comment Key or Definitions

The following key defines the comment descriptions represented in this report.  Any recommendations by the inspector to repair or replace indicates an item that should be further evaluated and corrected  as needed by a qualified contractor.

Inspected (IN) = This item was inspected.  If no other comments were made then it appeared sound and functioning as intended allowing for normal wear and tear.

Not Inspected (NI)= This item was not inspected. No representations of whether or not it is in satisfactory condition. Reasons for not inspecting will be noted..

Not Present (NA) = There are no exterior stairs, balcony or landings on this unit.

Balcony & Stairs (B&S) = This unit contains both a balcony and staircase.

Two Balcony's (2B) = This unit contains 2 balcony's.

Repair or Replace (RR) = Problems where observed that will require repairs or replacement. These will be indicated with a Red Flag graphic

Note: The first photo under each condo unit shows the unit number for reference only. Units where no problems where found may or may not have a unit number reference photo.

Scope of inspection - This condominium inspection is a partial inspection and is limited to the exterior appurtances, specifically the stairs, balcony's and landings.  Final Analysis Home Inspections makes no representation as to the condition of any other areas.

Remedies - Final analysis Home Inspections does not provide contracting services, repairs, or instructions on how to fix problems. It is recommended that licensed, qualified contractors be consulted for further evaluation repairs.

Depth of inspection - Though there are questionable areas regarding the original architecture and structural design of these porch and balcony structures, it is beyond the scope and purpose of this inspection to evaluate design deficiencies. This inspection is limited to only those defects, wear, deterioration and safety concerns that are within the confines of the original, pre-existing designs.

Disputes - If you feel an item has been reported in error, please submit this in writing at Final-Analysis.com . Be sure to include description of complaint, your name, contact number and address.

Top Table of Contents Bottom

 

Condo units
1.0 Unit 1601
Comments: Not applicable - No stairs or balcony
1.1 Unit 1603
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

1.1 Picture 1
1.1 Picture 2
(2) Observed loose, movable or detached hand rail at stairs. (Picture 3) Repair, replace and secure as needed to prevent movement.
1.1 Picture 3
(3) Staircase framing is unstable - Observed lateral movement and deflection of the staircase. (Picture 4) Tighten and add fasteners where needed. Consider adding vertical support post midway below staircase.
1.1 Picture 4
(4) Stair treads are loose, lifting, damaged and can be unsafe. (Picture 5) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety.
1.1 Picture 5
1.2 Unit 1605
Comments: Not applicable - No stairs or balcony
1.3 Unit 1607
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 1) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
1.3 Picture 1
(2) Stair treads are loose, lifting, damaged and can be unsafe.(Picture 1) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety.
1.3 Picture 2
(3) Floor boards are loose, warped, lifting or otherwise damaged at the stair landing. (Picture 2) repair, replace and fasten properly all floor boards where needed so that all are level, flat, secure and conform to original design.
1.3 Picture 3
1.3 Picture 4
1.4 Unit 1609
Comments: Not applicable - No stairs or balcony
1.5 Unit 1611
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Pickets are Loose, weathered, or cracked at Balcony. Repair or replace as needed using the proper fasteners.(Picture 2)
1.5 Picture 1
1.5 Picture 2
1.6 Unit 1613
Comments: Not applicable - No stairs or balcony
1.7 Unit 1615
Comments: Inspected, This unit contains both balcony & stairs
(1) Stair treads are loose, lifting, damaged and can be unsafe.(Picture 2) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety.
1.7 Picture 1
1.7 Picture 2
(2) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the landing. (Picture 3) These conditions are unsafe and can lead to detachment and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment.
1.7 Picture 3
Top Table of Contents Bottom

 

Condo units
2.0 Unit 1617
Comments: Not applicable - No stairs or balcony
2.1 Unit 1619
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

2.1 Picture 1
(2) Balcony structure is weathered, worn and weakened from exposure, age and deterioration. Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
(3) Floor boards are loose, warped, lifting or otherwise damaged at the balcony. repair, replace and fasten properly all floor boards where needed so that all are level, flat, secure and conform to original design.
2.2 Unit 1621
Comments: Not applicable - No stairs or balcony
2.3 Unit 1623
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
2.3 Picture 1
2.4 Unit 1625
Comments: Not applicable - No stairs or balcony
2.5 Unit 1627
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
2.5 Picture 1
2.6 Unit 1629
Comments: Not applicable - No stairs or balcony
2.7 Unit 1631
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Flashing is missing where staircase is attached to structure. (Picture 2) Flashing is recommended to prevent water intrusion into the wall.
2.7 Picture 1
2.7 Picture 2
Top Table of Contents Bottom

 

Condo units
3.0 Unit 1633
Comments: Not applicable - No stairs or balcony
3.1 Unit 1635
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

3.1 Picture 1
3.1 Picture 2
3.2 Unit 1637
Comments: Not applicable - No stairs or balcony
3.3 Unit 1639
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

3.3 Picture 1
3.3 Picture 2
3.4 Unit 1641
Comments: Not applicable - No stairs or balcony
3.5 Unit 1643
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
3.5 Picture 1
3.6 Unit 1645
Comments: Not applicable - No stairs or balcony
3.7 Unit 1647
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

3.7 Picture 1
3.7 Picture 2
(2) Pickets are Loose, weathered, or cracked at Balcony. Repair or replace as needed using the proper fasteners.(Picture 3)
3.7 Picture 3
(3) Stair risers are over cut and weakened at treads. Recommend sistering with riser reinforcements attached below steps. (Picture 4)
3.7 Picture 4
Top Table of Contents Bottom

 

Condo units
4.0 Unit 1649
Comments: Not applicable - No stairs or balcony
4.1 Unit 1651
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Pickets are Loose, poorly fastened and detached at stairs.(Picture 2) Repair or replace as needed using the proper fasteners.
4.1 Picture 1
4.1 Picture 2
4.2 Unit 1653
Comments: Not applicable - No stairs or balcony
4.3 Unit 1655
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
Balcony and steps have been painted
4.3 Picture 1
4.4 Unit 1657
Comments: Not applicable - No stairs or balcony
4.5 Unit 1659
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

4.5 Picture 1
4.5 Picture 2
(2) Balcony structure is weathered, worn and weakened from exposure, age and deterioration.(Picture 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
4.5 Picture 3
(3) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
4.6 Unit 1661
Comments: Not applicable - No stairs or balcony
4.7 Unit 1663
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1)
4.7 Picture 1
(2) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

4.7 Picture 2
Top Table of Contents Bottom

 

Condo units
5.0 Unit 1665
Comments: Not applicable - No stairs or balcony
5.0 Picture 1
5.1 Unit 1667
Comments: Not applicable - No stairs or balcony
5.1 Picture 1
5.2 Unit 1669
Comments: Not applicable - No stairs or balcony
5.2 Picture 1
5.3 Unit 1671
Comments: Not applicable - No stairs or balcony
5.3 Picture 1
5.4 Unit 1673
Comments: Not applicable - No stairs or balcony
5.4 Picture 1
5.5 Unit 1675
Comments: Not applicable - No stairs or balcony
5.5 Picture 1
5.6 Unit 1677
Comments: Not applicable - No stairs or balcony
5.6 Picture 1
5.7 Unit 1679
Comments: Not applicable - No stairs or balcony
5.7 Picture 1
Top Table of Contents Bottom

 

Condo units
6.0 Unit 1681
Comments: Not applicable - No stairs or balcony
6.0 Picture 1
6.1 Unit 1683
Comments: Not applicable - No stairs or balcony
6.1 Picture 1
6.2 Unit 1685
Comments: Not applicable - No stairs or balcony
6.2 Picture 1
6.3 Unit 1687
Comments: Not applicable - No stairs or balcony
6.3 Picture 1
6.4 Unit 1689
Comments: Not applicable - No stairs or balcony
6.4 Picture 1
6.5 Unit 1691
Comments: Not applicable - No stairs or balcony
6.5 Picture 1
6.6 Unit 1693
Comments: Not applicable - No stairs or balcony
6.6 Picture 1
6.7 Unit 1695
Comments: Not applicable - No stairs or balcony
6.7 Picture 1
Top Table of Contents Bottom

 

Condo units
7.0 Unit 1697
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Flashing is missing where balcony is attached to structure. (Picture 2) Flash recommended to prevent water intrusion into the wall.
7.0 Picture 1
7.0 Picture 2
7.1 Unit 1701
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
7.1 Picture 1
7.2 Unit 1705
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
7.2 Picture 1
7.3 Unit 1711
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
(1) Balcony is sagged - left balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

Pickets are Loose, weathered, or cracked at Left Balcony. Repair or replace as needed using the proper fasteners.(Picture 2)

7.3 Picture 1
7.3 Picture 2
(2) Balcony is sagged - Right balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

Pickets are Loose, weathered, or cracked at Right Balcony. Repair or replace as needed using the proper fasteners. (Picture 3)

7.3 Picture 3
Top Table of Contents Bottom

 

Condo units
8.0 Unit 1713
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
8.0 Picture 1
8.1 Unit 1719
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
8.1 Picture 1
8.2 Unit 1721
Comments: This unit contains 2 balcony's, This unit is satisfactory
8.3 Unit 1727
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Balcony's are sagged - Left and Right balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2-5) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony's should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

8.3 Picture 1
8.3 Picture 2
8.3 Picture 3
8.3 Picture 4
8.3 Picture 5
Top Table of Contents Bottom

 

Condo units
9.0 Unit 1729
Comments: Not applicable - No stairs or balcony
9.0 Picture 1
9.1 Unit 1731
Comments: Not applicable - No stairs or balcony
9.1 Picture 1
9.2 Unit 1733
Comments: Not applicable - No stairs or balcony
9.2 Picture 1
9.3 Unit 1735
Comments: Not applicable - No stairs or balcony
9.3 Picture 1
9.4 Unit 1737
Comments: Not applicable - No stairs or balcony
9.4 Picture 1
9.5 Unit 1739
Comments: Not applicable - No stairs or balcony
9.5 Picture 1
9.6 Unit 1741
Comments: Not applicable - No stairs or balcony
9.6 Picture 1
9.7 Unit 1743
Comments: Not applicable - No stairs or balcony
9.7 Picture 1
Top Table of Contents Bottom

 

Condo units
10.0 Unit 1745
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Balcony rails warped - Both left and right balcony 1x4 cap rails are warped and lifting. (Pictures 2 and 3) Repair or replaced as needed and attach securely using proper fasteners. Note: other balcony's use 2x4's for cap rails which are less likely to warp.
10.0 Picture 1
10.0 Picture 2
10.0 Picture 3
10.1 Unit 1747
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
10.1 Picture 1
10.2 Unit 1749
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
10.2 Picture 1
10.3 Unit 1751
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
10.3 Picture 1
Top Table of Contents Bottom

 

Condo units
11.0 Unit 1753
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
11.0 Picture 1
11.1 Unit 1755
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Both balcony structures are weathered, worn and weakened from exposure, age and deterioration. (Pictures 2 and 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

11.1 Picture 1
11.1 Picture 2
11.1 Picture 3
11.2 Unit 1757
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
11.2 Picture 1
11.3 Unit 1759
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

11.3 Picture 1
11.3 Picture 2
Top Table of Contents Bottom

 

Condo units
12.0 Unit 1761
Comments: Not applicable - No stairs or balcony
12.0 Picture 1
12.1 Unit 1763
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

12.1 Picture 1
12.1 Picture 2
(2) Pickets are Loose, weathered, or cracked at Stairs. Repair or replace as needed using the proper fasteners. (Picture 3)
12.1 Picture 3
12.2 Unit 1765
Comments: Not applicable - No stairs or balcony
12.2 Picture 1
12.3 Unit 1767
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Staircase frame is loose, separating, or poorly secured where the stair case attaches to the bottom landing. (Picture 2) These conditions are unsafe and can lead to detachment and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment.
12.3 Picture 1
12.3 Picture 2
12.4 Unit 1769
Comments: Not applicable - No stairs or balcony
12.5 Unit 1771
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Flashing is missing where staircase is attached to structure.(Picture 1) Flash as needed to prevent water intrusion into the wall.
12.5 Picture 1
12.6 Unit 1773
Comments: Not applicable - No stairs or balcony
12.6 Picture 1
12.7 Unit 1775
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Staircase frame is loose, separating, or poorly secured where the stair case attaches to the lower landing. (Picture 2) These conditions are unsafe and can lead to detachment and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment.
12.7 Picture 1
12.7 Picture 2
Top Table of Contents Bottom

 

Condo units
13.0 Unit 615
Comments: Not applicable - No stairs or balcony
13.0 Picture 1
13.1 Unit 617
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
13.1 Picture 1
13.2 Unit 619
Comments: Not applicable - No stairs or balcony
13.2 Picture 1
13.3 Unit 621
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
13.3 Picture 1
13.4 Unit 1742
Comments: Not applicable - No stairs or balcony
13.4 Picture 1
13.5 Unit 1744
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the landing. (Picture 2) These conditions are unsafe and can lead to detachment and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment.
13.5 Picture 1
13.5 Picture 2
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
13.5 Picture 3
13.6 Unit 1746
Comments: Not applicable - No stairs or balcony
13.6 Picture 1
13.7 Unit 1748
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Observed loose, movable or detached hand rail at stairs. Repair, replace and secure as needed to prevent movement.
13.7 Picture 1
(2) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the landing. These conditions are unsafe and can lead to detachment and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment.
13.7 Picture 2
Top Table of Contents Bottom

 

Condo units
14.0 Unit 623
Comments: Not applicable - No stairs or balcony
14.0 Picture 1
14.1 Unit 625
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

14.1 Picture 1
14.1 Picture 2
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Pictures 3 - 5) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
14.1 Picture 3
14.1 Picture 4
14.1 Picture 5
14.2 Unit 627
Comments: Not applicable - No stairs or balcony
14.2 Picture 1
14.3 Unit 629
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Observed loose, movable or detached hand rail at stairs. (Picture 2) Repair, replace and secure as needed to prevent movement.
14.3 Picture 1
14.3 Picture 2
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
14.3 Picture 3
14.4 Unit 1710
Comments: Not applicable - No stairs or balcony
14.4 Picture 1
14.5 Unit 1712
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
14.5 Picture 1
14.6 Unit 1714
Comments: Not applicable - No stairs or balcony
14.6 Picture 1
14.7 Unit 1716
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
14.7 Picture 1
Top Table of Contents Bottom

 

Condo units
15.0 Unit 631
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Right and left balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge.(Pictures 2 and 3)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

15.0 Picture 1
15.0 Picture 2
15.0 Picture 3
15.1 Unit 633
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Both balcony structures are weathered, worn and weakened from exposure, age and deterioration. (Pictures 2 and 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
15.1 Picture 1
15.1 Picture 2
15.1 Picture 3
15.2 Unit 1772
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
15.2 Picture 1
15.3 Unit 1774
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
15.3 Picture 1
Top Table of Contents Bottom

 

Condo units
16.0 Unit 651
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

16.0 Picture 1
16.0 Picture 2
16.1 Unit 653
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
16.1 Picture 1
16.2 Unit 1666
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
16.2 Picture 1
16.3 Unit 1668
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

Cap rails warped lifting at both balcony's. (Picture 1) Repair or replace as needed using proper materials and fasteners.

16.3 Picture 1
16.3 Picture 2
Top Table of Contents Bottom

 

Condo units
17.0 Unit 643
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

17.0 Picture 1
17.0 Picture 2
17.1 Unit 645
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Right balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

17.1 Picture 1
17.1 Picture 2
17.2 Unit 647
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and Right balcony's are sagged - balcony's is noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

17.2 Picture 1
17.2 Picture 2
17.2 Picture 3
17.3 Unit 649
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Right balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

17.3 Picture 1
17.3 Picture 2
Top Table of Contents Bottom

 

Condo units
18.0 Unit 635
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
18.0 Picture 1
18.1 Unit 637
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
18.1 Picture 1
18.2 Unit 639
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Warped and lifting cap rails observed at both balcony's. (Pictures 2 and 3) Repair or replace as needed using proper materials and fasteners.

Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

18.2 Picture 1
18.2 Picture 2
18.2 Picture 3
18.3 Unit 641
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2 and 3)The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

18.3 Picture 1
18.3 Picture 2
18.3 Picture 3
Top Table of Contents Bottom

 

Condo units
19.0 Unit 600
Comments: Not applicable - No stairs or balcony
19.0 Picture 1
19.1 Unit 602
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

19.1 Picture 1
19.1 Picture 2
(2) Observed loose, movable or detached hand rail at stairs. Repair, replace and secure as needed to prevent movement.
(3) Pickets are Loose, weathered, or cracked at Balcony. (Picture 2) Repair or replace as needed using the proper fasteners.
19.1 Picture 3
(4) Stair treads are loose, lifting, damaged and can be unsafe. (Picture 3) Repair, replace and fasten correctly as needed in a manner that will restore function, esthetics and safety.
19.1 Picture 4
19.2 Unit 604
Comments: Not applicable - No stairs or balcony
19.2 Picture 1
19.3 Unit 606
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
19.3 Picture 1
19.4 Unit 608
Comments: Not applicable - No stairs or balcony
19.4 Picture 1
19.5 Unit 610
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
19.5 Picture 1
19.6 Unit 612
Comments: Not applicable - No stairs or balcony
19.6 Picture 1
19.7 Unit 614
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
19.7 Picture 1
Top Table of Contents Bottom

 

Condo units
20.0 Unit 616
Comments: Not applicable - No stairs or balcony
20.0 Picture 1
20.1 Unit 618
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

20.1 Picture 1
20.1 Picture 2
(2) Staircase framing is unstable - Observed lateral movement and deflection of the staircase.(Picture 3) Tighten and add fasteners where needed. Consider adding vertical support post midway below staircase.
20.1 Picture 3
(3) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 4) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
20.1 Picture 4
20.2 Unit 620
Comments: Not applicable - No stairs or balcony
20.2 Picture 1
20.3 Unit 622
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

20.3 Picture 1
20.3 Picture 2
20.4 Unit 624
Comments: Not applicable - No stairs or balcony
20.5 Unit 626
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Pictures 2-4) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
20.5 Picture 1
20.5 Picture 2
20.5 Picture 3
20.5 Picture 4
(2) Staircase frame is loose, separating, or poorly secured where the stair case attaches to the upper landing.(Picture 4) These conditions are unsafe and can lead to detachment and cause injury. Have properly secured with adequate framing, fasteners or brackets to ensure a substantially secure and permanent attachment.
20.5 Picture 5
20.6 Unit 628
Comments: Not applicable - No stairs or balcony
20.6 Picture 1
20.7 Unit 630
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

20.7 Picture 1
20.7 Picture 2
(2) Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Picture 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
20.7 Picture 3
Top Table of Contents Bottom

 

Condo units
21.0 Unit 632
Comments: Not applicable - No stairs or balcony
21.0 Picture 1
21.1 Unit 634
Comments: Not applicable - No stairs or balcony
21.1 Picture 1
21.2 Unit 636
Comments: Not applicable - No stairs or balcony
21.2 Picture 1
21.3 Unit 638
Comments: Not applicable - No stairs or balcony
21.3 Picture 1
21.4 Unit 640
Comments: Not applicable - No stairs or balcony
21.4 Picture 1
21.5 Unit 642
Comments: Not applicable - No stairs or balcony
21.5 Picture 1
21.6 Unit 644
Comments: Not applicable - No stairs or balcony
21.6 Picture 1
21.7 Unit 646
Comments: Not applicable - No stairs or balcony
21.7 Picture 1
Top Table of Contents Bottom

 

Condo units
22.0 Unit 648
Comments: Not applicable - No stairs or balcony
22.0 Picture 1
22.1 Unit 650
Comments: Not applicable - No stairs or balcony
22.1 Picture 1
22.2 Unit 652
Comments: Not applicable - No stairs or balcony
22.2 Picture 1
22.3 Unit 654
Comments: Not applicable - No stairs or balcony
22.3 Picture 1
22.4 Unit 1601
Comments: Not applicable - No stairs or balcony
22.4 Picture 1
22.5 Unit 1603
Comments: Not applicable - No stairs or balcony
22.5 Picture 1
22.6 Unit 1605
Comments: Not applicable - No stairs or balcony
22.6 Picture 1
22.7 Unit 1607
Comments: Not applicable - No stairs or balcony
22.7 Picture 1
Top Table of Contents Bottom

 

Condo units
23.0 Unit 656
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
RIGHT Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

23.0 Picture 1
23.0 Picture 2
23.1 Unit 658
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
23.1 Picture 1
23.2 Unit 1600
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
(1) Left and Right Balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2 and 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

23.2 Picture 1
23.2 Picture 2
23.2 Picture 3
(2) LEFT Balcony structure is weathered, worn and weakened from exposure, age and deterioration. Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
(3) Pickets are Loose, weathered, or cracked at LEFT Balcony. Repair or replace as needed using the proper fasteners.
23.3 Unit 1602
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
23.3 Picture 1
Top Table of Contents Bottom

 

Condo units
24.0 Unit 660
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Picture 2 and 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

24.0 Picture 1
24.0 Picture 2
24.0 Picture 3
24.1 Unit 662
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
24.1 Picture 1
24.2 Unit 664
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
24.2 Picture 1
24.3 Unit 666
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge.(Picture 2-4) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

24.3 Picture 1
24.3 Picture 2
24.3 Picture 3
24.3 Picture 4
Top Table of Contents Bottom

 

Condo units
25.0 Unit 668
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
25.0 Picture 1
25.1 Unit 670
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge.(Pictures 1 and 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

Right balcony cap rail is warped, loose and lifting. repair or replace as needed.(Picture 2)

25.1 Picture 1
25.1 Picture 2
25.2 Unit 672
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
25.2 Picture 1
25.3 Unit 674
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
25.3 Picture 1
Top Table of Contents Bottom

 

Condo units
26.0 Unit 676
Comments: Inspected, This unit contains 2 balcony's, This unit is satisfactory
26.0 Picture 1
26.1 Unit 678
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
left and Right balcony's are sagged - balcony's are noticeably un-level and is pitched downwards towards the outer edge or are un-level left to right. (Pictures 2-3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

26.1 Picture 1
26.1 Picture 2
26.1 Picture 3
26.2 Unit 680
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge. (Picture 1) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

26.2 Picture 1
26.3 Unit 682
Comments: Inspected, Problems observed, Repair or Replace, This unit contains 2 balcony's
Left and Right balcony's are sagged - Both balcony's are noticeably un-level and is pitched downwards towards the outer edge. (Pictures 2 and 3) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

Warped, Lifting cap rail's - Both 1x4 cap rails on balcony's are warped and lifting. (Pictures 2 and 3) Repair or replace as needed using the correct fasteners. Note: other balcony's are using 2x4's which are less likely to warp.

26.3 Picture 1
26.3 Picture 2
26.3 Picture 3
Top Table of Contents Bottom

 

Condo units
27.0 Unit 1600
Comments: Not applicable - No stairs or balcony
27.0 Picture 1
27.1 Unit 1602
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
27.1 Picture 1
27.2 Unit 1604
Comments: Not applicable - No stairs or balcony
27.2 Picture 1
27.3 Unit 1606
Comments: Inspected, This unit contains both balcony & stairs, This unit is satisfactory
27.3 Picture 1
27.4 Unit 1608
Comments: Not applicable - No stairs or balcony
27.4 Picture 1
27.5 Unit 1610
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
(1) Balcony is sagged - balcony is noticeably un-level and is pitched downwards towards the outer edge.(Picture 2) The balcony framing and attachments do not appear to be sufficiently designed to bear the weight of the balcony and may fail with additional weight loads which is a safety concern.

At a minimum, the balcony should be re-leveled and the existing bolts tightened and additional bolts added where needed.

Balcony structure is also weathered, worn and weakened from exposure, age and deterioration. (Picture 2) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.

Preferably it is recommend that further evaluation be completed by a structural engineer or contractor who can determine if and how modifications to attachments or additional reinforcements may be needed and installed to ensure safe and sound structural design.

27.5 Picture 1
27.5 Picture 2
(2) Balcony cap rail is loose warped, lifting. (Picture 3) Repair or replace as needed using proper materials and fasteners. Note: other balcony's use 2x4's which are less likely to fail.
27.5 Picture 3
(3) Fasteners are loose, improper and failing at stair rails and post supports. (Pictures 4 and 5) Repair, Replace and reinforce as needed using proper fastening. .
27.5 Picture 4
27.5 Picture 5
27.6 Unit 1612
Comments: Not applicable - No stairs or balcony
27.6 Picture 1
27.7 Unit 1614
Comments: Inspected, Problems observed, Repair or Replace, This unit contains both balcony & stairs
Staircase structure is weathered, worn and weakened from exposure, age and deterioration. (Pictures 2 and 3) Repair or replace as needed in a manner that with restore stability, function, safety and conform to original design.
27.7 Picture 1
27.7 Picture 2
27.7 Picture 3