Home
Inspection Report
rehabbed property
|
||||||||
" We see what's missing " Final Analysis Home Inspections
|
||||||||
Prepared exclusively for Name removed for privacy
|
||||||||
xxxx Argonne Ave Norfolk, VA 23505 Note: This is an actual home inspection. Other than removal of name and address, nothing has been doctored for show. |
||||||||
This investment property was renovated by a son in law whose sympathetic father in law hired to help him financially. He said it backfired on him and he regretted it. |
||||||||
|
||||||||
Report ID:
bt021207
|
||||||||
Inspection
Date:
2/12/2007
|
||||||||
Inspected By:
Dan Rogers
|
||||||||
757.495.2300 |
||||||||
Date: 2/12/2007 | Time: 1:00 PM | Report ID: barton021207 |
Property: xxxx Argonne Ave Norfolk, VA 23505 |
Customer: removed for privacy |
Real Estate Professional: Bill Dorris |
Client Is Present: Yes | Age Of Home: 1941 | Weather: Clear |
Temperature: 53 | Rain in last 3 days: No | Square feet: 1576 |
Inspection type: Home Buyers Inspection | Structure type: 1 story single family residence (ranch) | Occupancy: property is vacant |
Reading this report - The report is broken down by each major system . At the beginning of each system section is an overview which describes what the inspector is required and not required to inspect (ASHI standards). The overview may also contain some general photos of that system. Then you will see the list the styles & materials identified for that system. Below that is the system components that are inspected. This is where the observations are reported along with any supporting photos. Also under each system component there is a general comment category which will contain one or more of the following: Satisfactory, Discrepant Item, Informational Disclosures, Maintenance Recommendations, Not Inspected.
Inspection issues or concerns are flagged and broken down to 3 categories: Defective (repair or replace), Informational Disclosures (environmental, material or safety concerns), Maintenance (recommended or preventative). Any problems that fall under these categories will also be listed in the General Summary and on the corresponding summary for that category. These itemized summaries help you quickly identify the nature of the problem and therefore your course of action.
Defect Summary - List of just Defects, Repair or Replace items.
Info, Safety & Disclosure Summary - List of just Safety issues and Informational Disclosures
Maintenance Summary - List of just Maintenance, issues, concerns and recommendations.
A thorough home inspection was completed at the subject property in accordance with ASHI standards.
This home has recently undergone a significant remodel affecting all the systems. Much of the workmanship is less than typically accepted standards of quality. Most of which is marginal, amateur and does not meet professional trade standards. Some problems are bigger than others but all are consistent in weighing heavily on the overall inherent condition of the property.
It is beyond the scope of this inspection to create a "punch list" of repair items. When the overwhelming majority of findings reflect less than satisfactory conditions of a system, then the issues and items reported are a sampling of condition which are merely intended to qualify the findings in an attempt to establish an overall consensus of the systems condition and the level of corrective action needed.. Under these circumstances the reported items can not and are not all inclusive. The systems where this is the case, need to be systematically and thoroughly evaluated, repaired or replaced as needed by a qualified contractor. The objective outcome of all repairs should meet or exceed professional, proper and permanent standards of good repair. Where there is a significant amount of rework that needs to be done, it is highly recommended that a re-inspection be done again after all work is complete.
Please be advised that most municipal zoning and building agencies require permits and code inspections for this magnitude of remodeling. You should obtain this for your own protection for fire, insurance, safety and legal compliance purposes.
GENERAL ROOF CONDITION: GOOD: Average condition& performance | ROOF INSPECTION LIMITATIONS: Typical inspection access | REMAINING SERVICE LIFE: 50% - Typical aging& wear - No immediate concern of replacement expense |
ROOF AS SEEN FROM: ladder | SYSTEM INSPECTED?: Yes | ROOF STYLES& DESIGN: Gable |
ROOF COVERING MATERIALS: ASPHALT: Felt 3 tab shingles | FLASHING MATERIAL: Aluminum | SKY LIGHT (S): NONE |
ACTIVE ROOF OR FLASHING LEAKS: Yes | GUTTERS& DOWNSPOUTS: Attached:partial Gutter Material: Aluiminum | ATTIC VENTILATION: Roof |
Layers of shingles: one |
1.0 | ROOF COVERINGS Comments - Satisfactory, Functional | ||
(2) There are several punctured holes through the roof shingles where there is no roof decking in the area above the attic access hatch where the roof transitions to the back addition.( Picture 1,2 ) |
1.1 | ROOF DECKING Comments - Satisfactory, Functional |
1.2 | FLASHING or JOINT MATERIALS Comments - Satisfactory, Functional | |
Flashing is missing at roof transition, left side towards rear. Observed exposed wood and susceptibility for water intrusion. ( Picture 1 ) |
1.3 | GUTTERS, ROOF DRAINAGE SYSTEMS Comments - Satisfactory, Functional, Informational notes and disclosures | ||
No gutters installed in several areas including left side and rear. The left side prohibits install of gutters because service cable is now in the way.( Picture 1 ) |
1.4 | SKYLIGHTS Comments - Not Present |
1.5 | VENTILATION Comments - Discrepant item, Repair or Replace | ||
(1) There are no intake (soffit) vents to support roof vents. ( Picture 1 ) You must have equal make up air for adequate attic ventilation. The original gable vents are not adequate for this purpose. | |||
(2) Attic gable vent vermin screening is missing, birds have invaded, Notice the big pile of nesting straw. ( Picture 3 ) |
GENERAL CONDITION: EXTERIOR: FAIR: Below average condition& performance | SYSTEM INSPECTED?: Yes | EXTERIOR LIMITATIONS: Typical |
SIDING MATERIAL: VINYL BRICK VENEER | EXTERIOR TRIM: WOOD VINYL AND/OR ALUMINIUM | PRIMARY WINDOWS: DOUBLE-HUNG GLAZING: THERMAL/INSULATED MATERIAL: PLASTIC/ VINYL |
EXTERIOR ENTRY DOORS: METAL | STEPS AND OR RAILS: NA | GARAGES AND OR CARPORTS: ATTACHED |
FIRE ESCAPES: NA | GARAGE AUTO OPENER: N/A | GARAGE DOOR MATERIAL: METAL |
GARAGE DOOR TYPE: ONE MANUAL | DRIVEWAY: CONCRETE |
2.0 | WALL CLADDING FLASHING AND TRIM Comments - Discrepant item, Repair or Replace | ||
(1) Unfinished plywood siding, No pan flashing at bottom has promoted rot. rear of garage. Siding is also separating at the seams. ( Picture 2 ) | |||
(2) Exposed wood, metal trim flashing is missing, possible water intrusion point. left side wall towards rear. ( Picture 3 ) | |||
(3) A random sampling of the vinyl siding revealed that the panels are loose in multiple areas around the entire exterior. Closer examination shows that many of the nails are not catching a solid stud. ( Picture 4 ) Have all siding inspected and secured properly. | |||
(4) Refrigerant line wall penetration is not sealed. ( Picture 5 ) |
2.1 | DOORS (Exterior) Comments - Discrepant item, Repair or Replace | |
(1) Rear garage door or wall closure is missing ( Picture 1 ) | ||
(2) Right side entry door does not latch and seal properly, the keeper is missing. ( Picture 2 ) This same door also does not have a paint seal. factory powder primer finish only will not stop rusting of door skin. |
2.2 | WINDOWS Comments - Satisfactory, Functional |
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS Comments - Preventative maintenance recommended | |
(1) Evidence of poor drainage and standing water at front entry. Observed dirt and silt deposits, heavy caulk attempted at threshold, drainage groves in concrete edges.( Picture 1 ) Cannot determine if this has been cured. Inquire with current owner. | ||
(2) Evidence of poor drainage, standing water at left rear walk. Observed water stains, reversed slope where grade meets concrete, downspout drainage onto walkway. ( Picture 2 ) |
2.4 | EAVES, SOFFITS, FASCIAS, RAKES, and EXTERIOR TRIM Comments - Satisfactory, Functional |
2.5 | DETACHED SHED Comments - Not Present |
2.6 | Garage door opener safety reverse Comments - Not Present |
GENERAL CONDITION: Foundation and Structure: FAIR: Below average condition& performance | SYSTEM INSPECTED?: Yes | FOUNDATION/STRUCTURE LIMITATIONS: TYPICAL ACCESS |
FOUNDATION TYPE: Slab | STRUTURE AND MATERIALS: FRAME: WOOD CONCRETE SLAB | Foundation ventilation: N/A - slab construction |
EXTERIOR DRAINAGE: SITE: LEVEL Marginal or inadequate drainage Poorly graded | METHOD USED TO OBSERVE CRAWLSPACE: NO CRAWLSPACE | FLOOR STRUCTURE: NOT VISIBLE |
WALL STRUCTURE: 2 X 4 WOOD | VIEWED ATTIC SPACE FROM:: WALKED | CEILING STRUCTURE: 2X4 |
ROOF STRUCTURE: STICK-BUILT 2X4 RAFTERS 2 X 6 RAFTERS PLYWOOD | ATTIC ACCESS: Ceiling hatch |
3.0 | FOUNDATION & STRUCTURE (Report signs of abnormal or harmful water penetration into the building or signs of abnormal settlement, structural failure, wood destroying insects & fungus.) Comments - Satisfactory, Functional, Informational notes and disclosures |
Evidence of termites detected in the attic framing and roof decking. Beware, a visual inspection can not detect termites inside concealed areas. In light of the evidence, You may want to consider a more invasive type inspection be performed by a licensed exterminator. |
3.1 | FOUNDATION VENTILATION & VAPOR BARRIER Comments - Not Present |
3.2 | FLOORS (Structural) Comments - Not Inspected |
3.3 | WALLS (Structural) Comments - Satisfactory, Functional |
3.4 | COLUMNS OR PIERS Comments - Not Present |
3.5 | CEILINGS (structural) Comments - Satisfactory, Functional |
3.6 | ROOF STRUCTURE AND ATTIC Comments - Discrepant item, Repair or Replace | |||
(1) Improper workmanship of load bearing framing rafters observed in attic. (pictures 1,2,3) There are several areas where rafters where scabbed and rafter tails added. the pieces that are load bearing must have continuous load transfer to load bearing supports. | ||||
(2) Evidence of significant termite damage in several areas of attic framing, rafters and decking. the pictures show a sampling. have evaluated and repaired as needed. | ||||
(3) 2x4 16" o/c rafters do not appear to meet load requirements for the existing roof span and load. Have further evaluated and repaired as needed by a framing contractor. | ||||
(4) Improper framing, rafters hang below ridge board and there are no collar ties installed. Have all areas further evaluated and repaired as needed by a framing contractor. ( Picture 8 ) |
3.7 | LOT& GRADING Comments - Informational notes and disclosures | ||
(1) Lot is level and was not ever properly graded to provide positive drainage away from structure. Noted several drains and levies have been installed at walkways. This is typical for this age of construction. It appears that the lot drainage problem has been cured but hard to tell how it would handle a large volume of rain. | |||
(2) Side of driveway is sunken and eroded, will hold water. fill, pack, grade and seed as needed. ( Picture 1,2 ) |
GENERAL SYSTEM CONDITION: plumbing: POOR: Sub-standard condition& performance | SYSTEM INSPECTED?: Yes | Plumbing Limitations: Typically accessible areas |
Main water supply pipe (street service): Buried - concealed - Not determined | Supply pipes and distribution materials ( visable ): COPPER PEX tubing | Waste Piping materials (visable): PVC Iron (antiquated) |
Water pressure: Noticeable pressure drop when more than one faucet is opened. restricted flow in one or more faucets/fixtures | Cross connects observed: No | Water supply system (potable): Public utility |
Waste system (sewage): Public sewage | Fixtures & faucets observed (checked for leaks & fill & drain function only): TUBS SINKS TOILETS SHOWERS | Hot water source: Electirc 40 gallon tank |
REMAINING SERVICE LIFE of Water heater: 100% - New or Upgraded - No concern of replacement expense | Drainage at Fixtures: Slow or backing up Stopped up |
4.0 | INTERIOR DRAINS, SUPPLY PIPES, FIXTURES AND VENT SYSTEMS Comments - Discrepant item, Repair or Replace | ||
(1) Kitchen sink drain is not vented to atmosphere and is back venting through its own drain. ( Picture 1 )
Guest bathtub is stopped up. Guest toilet is backed up and overflowing. Guest sink basin is loose in cabinet. ( Picture 2 ) Guest bath sink drain is not vented to exterior atmosphere. Kitchen sink double drains are not plumbed properly. One drains towards and into disposal unit. Could not locate a soil vent for the clothes washing machine. | |||
(2) Note: Could not test washing machine drain without washing machine installed. | |||
(3) DISCLOSURE: This home contains antiquated style galvanized and/or iron (steel) drains. These type of drains have a limited service life of approx 30 - 50 years. They rust and constrict internally from corrosion. They can be reamed out a few times but inadvisably have to be replaced. Replacing pipes in home that are built on concrete slabs can be very expensive because it involved removal of flooring and concrete. |
4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments - Discrepant item, Repair or Replace |
Adequate water pressure could not be maintained when two or more faucets are opened, especially the hot water. |
4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments - Discrepant item, Repair or Replace | ||
Water heater is notably undersized. Typical for this size house is normally 48 - 52 gallon electric.( Picture 1 )
Water heater T&P discharge pipe is missing. Should be installed for safety and discharged to the exterior of structure. Water heater drain pipe is missing from overflow pan. |
4.3 | Fixtures Tubs and faucets Comments - Discrepant item, Repair or Replace | ||
Guest bath tub and shower has two diverters and neither one works.
Master bath toilet continues to run after flush.( Picture 1 ) Kitchen pipe on outside wall and under cabinet are not insulated from freezing.( Picture 2 ) |
4.4 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments - Informational notes and disclosures |
Undetermined |
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Comments - Informational notes and disclosures | |
Gas fuel system has been abandoned, meter still in place. ( Picture 1 ) |
4.6 | SUMP PUMP Comments - Not Present |
GENERAL SYSTEM CONDITION: Electrical: FAIR: Below average condition& performance | ELECTRICAL LIMITATIONS: TYPICAL | EXTERIOR SERVICE AND METER: OVERHEAD SERVICE |
SERVICE ENTRY WIRING: Aluminum 4/0 | INTERIOR COMPONENTS OBSERVED: RECEPTACLES SWITCHES LIGHT FIXTURES GFCI | EXTERIOR COMPONENTS OBSERVED: LIGHT FIXTURES |
MAIN PANEL(s) Type & Capacity: 200 AMP | BRANCH WIRE 15 and 20 AMP: COPPER | WIRING system & material: ROMEX |
Location of Main Panel: Laundry or utility room |
5.0 | SERVICE ENTRANCE WIRING Comments - Discrepant item, Repair or Replace | |
Service feed wire is mounted to fascia trim. These feeds are typically mounted under the soffit, out of the way of the elements, somewhat protected from ladders and equipment which can also be dangerous. This has also prohibited installation of gutters which seem much needed on this property with poor drainage. |
5.1 | MAIN SERVICE - Main panel, sub-panels, grounds & bonds, Capacities, Ratings, Overcurrent protection & distribution. Comments - Informational notes and disclosures |
Could not determine or locate main ground bond to piping and earth ground. |
5.2 | WIRING - Amperage & Voltage protection and compatibility of branch wiring & overcurrent devices, conductor material. ( breakers, fuses vs. size of conductors.) Comments - Satisfactory, Functional |
5.3 | EXTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. Comments - Discrepant item, Repair or Replace | |
Garage outlet is missing cover plate.( Picture 1 ) |
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. Comments - Discrepant item, Repair or Replace | ||
(1) All kitchen wiring is on a single 110 vac, 20 amp GFCI feed. This includes all outlets, microwave, disposal, dishwasher, refrigerator. This presents numerous problems included but not limited to overloaded circuit, GFCI trip when fridge compressor is in locked rotor startup, etc. This was only detected because testing the GFCI caused shutdown of all circuits. This type of amateur workmanship does not instill confidence in other branch wiring that cannot be tested during a home inspection. This house also has a some old rag type wiring in use but most is concealed in the walls and ceilings. Have all branch wiring further evaluated and repaired as needed by a qualified electrical contractor.
| |||
(2) Fire hazard - Incandescent light fixtures used inside closets. recommend replacing with low heat fluorescent. | |||
(3) Water heater wiring and conduit are excessively long. |
5.5 | GFCI (ground fault circuit interrupts are safety outlets in "wet area" locations. i.e. baths, garage, exterior, kitchen, etc.) Comments - Satisfactory, Functional |
5.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Comments - Informational notes and disclosures | |
Service panel, located in laundry room does not appear to meet minimum clearance requirements to the left wall. have this reviewed and approved by an electrical contractor. |
5.7 | Smoke detectors Comments - Not Inspected |
GENERAL RATING: FAIR: Below average condition& performance | LIMITS ON INSPECTION: TYPICAL | TYPE OF FUEL: HEAT PUMP (FORCED AIR) |
EQUIPMENT LOCATION: Attic Exterior | THERMOSTAT TYPE: MECHANICAL | THERMOSTAT LOCATION: Central hall |
THERMOSTAT CONDITION: FUNCTIONAL | WARM AIR SYSTEMS: HEAT PUMP:ELECTRIC BACK UP | FIREPLACE/FLUES: None |
NUMBER OF HEAT SYSTEMS (excluding wood): ONE | HEAT SYSTEM BRAND: GOODMAN | DUCTWORK: Insulated metal insulated flex duct |
FILTER TYPE: DISPOSABLE | OPERABLE FIREPLACES: NONE | NUMBER OF WOODSTOVES: NONE |
REMAINING SERVICE LIFE: 75% - Typical condition& minimal wear - No concern of replacement expense |
6.0 | HEATING EQUIPMENT Comments - Satisfactory, Functional | |||
(1) Heat pump data. ( Picture 1 ) note heat pump was tested in heat mode. | ||||
(2) Could not find a drain pipe on the Auxiliary attic condensate drip pan. ( Picture 3 )
Main condensate drain does not contain a trap or vent. ( Picture 2 ) Thermostat wiring and power wire conduit are loose and vulnerable to damage.( Picture 4 ) |
6.1 | NORMAL OPERATING CONTROLS Comments - Satisfactory, Functional |
6.2 | CHIMNEYS, FLUES AND VENTS Comments - Not Present |
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments - Discrepant item, Repair or Replace | |||||
Multiple areas observed where duct connections are poorly done. No mastic or adhesive is used on flanges, Duct tape is loose and failing at many of the connections and plenum seams allowing air leaks. make shift flange caps are loose and separating. have all the duct work further evaluated and repaired as needed by an HVAC contractor.
Ceiling diffuser over side entry door is loose and falling. |
6.4 | SPACE HEATING Comments - Not Present |
6.5 | GAS/LP FIRELOGS AND FIREPLACES Comments - Not Present |
6.6 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments - Satisfactory, Functional |
GENERAL INSULATION RATING (subjective to age of home): POOR: Sub-standard condition& performance | Insulation inspection limitations: TYPICAL | TYPE: FIBERGLASS |
ATTIC INSULATION: NONE | R- VALUE: NONE | VENTILATION: GABLE VENTS 8x8 Static Roof vents |
BATH EXHAUST FAN TYPES: FAN ONLY Window | FLOOR INSULATION: NONE | WALL INSULATION: UNKNOWN Little or no access - can't determine |
7.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) Comments - Discrepant item, Repair or Replace | ||||
No insulation installed over main part of house. ( Picture 1 )
Insulation is substandard or missing in the back areas of ceiling.( Picture 3,4 ) |
GENERAL RATING: FAIR: Below average condition& performance | INTERIOR LIMITATIONS: TYPICAL | APPLIANCES: DISHWASHER RANGE BURNERS OVEN ELEMENTS HOOD FANS/VENTS MICROWAVE GARBAGE DISPOSER BATH/DRYER VENTS |
WALLS AND CEILING MATERIAL: Sheet rock& plaster | INTERIOR OF WINDOWS: Functional | FLOOR COVERING(S): CARPET TILE |
INTERIOR DOORS: HOLLOW CORE RAISED PANEL | CABINETRY: MELAMINE | COUNTERTOP: WOOD |
DRYER VENT: NONE |
8.0 | CEILINGS Comments - Satisfactory, Functional |
8.1 | WALLS Comments - Discrepant item, Repair or Replace | |||||||
Less than quality plaster and paint finish workmanship. paint is uneven and inconsistent. ( Picture 2 ) most of the plaster work surface finish is inconsistent ( Picture 3 ) and corners and seams are not pointed up professionally. There are multiple shrinkage and stress cracks around doors and seams. ( Picture 7 ) ( Picture 4 )
The kitchen pantry is not taped, plaster or pointed at all and there are gaps open to the attic.( Picture 5 ) Particle board shelving is very poor as it will sag and give way over time. One closet has no shelves or rods installed. Hall closet shelf cleats are installed with finish nails and will not hold weight.( Picture 6 ) |
8.2 | FLOORS Comments - Discrepant item, Repair or Replace, Preventative maintenance recommended |
Carpet in the rear of house is heavily soiled and is also coming loose in some areas.
Kitchen tile grout workmanship is poor and it does not appear to have a sealer. |
8.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments - Not Present |
8.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments - Discrepant item, Repair or Replace | |||||
Cabinet over fridge location is cracked at mounts and loose on wall. ( Picture 1 )
Counter tops in kitchen and bath are substandard in designed and installation. Wood back splashes are used which will rot. ( Picture 5 ) Wood trim edge is used which will rot.( Picture 4 ) Sinks and basins are not properly secured and seal.( Picture 3 ) Counter tops are not adequately secured to base cabinets.( Picture 2 ) Many of the cabinet doors are loose and/or crooked. |
8.5 | DOORS (REPRESENTATIVE NUMBER) Comments - Discrepant item, Repair or Replace | ||
Many of the interior doors doe not close, latch or operate as designed. Some are missing hardware, closet sliders are missing track retainers at bottom. All the doors should be gone through and reworked or repaired as needed. |
8.6 | WINDOWS (REPRESENTATIVE NUMBER) Comments - Satisfactory, Functional | |
(2) Right rear wooden window is not operable. ( Picture 1 ) |
8.7 | INTERIOR INSPECTION ACCESSIBILITY Comments - Satisfactory, Functional, Informational notes and disclosures | ||
Lots of empty beer cans are hidden everywhere. ( Picture 1 )
Garage is not accessible for inspection due to construction clutter.( Picture 2 ) |
8.8 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments - Discrepant item, Repair or Replace | |
No Dryer vent installed. |
GENERAL RATING: GOOD: Average condition& performance | DISHWASHER: Functional | DISPOSER: Functional |
EXHAUST/RANGE HOOD: Fucntional | RANGE/OVEN: Functional | BUILT-IN MICROWAVE: Functional |
REFRIGERATOR: NONE | DRYER POWER SOURCE: 22O ELECTRIC |
9.0 | DISHWASHER Comments - Satisfactory, Functional |
9.1 | RANGES/OVENS/COOKTOPS Comments - Satisfactory, Functional |
9.2 | RANGE HOOD Comments - Satisfactory, Functional |
9.3 | FOOD WASTE DISPOSER Comments - Satisfactory, Functional |
9.4 | MICROWAVE COOKING EQUIPMENT Comments - Satisfactory, Functional |
|
757-495-2300
|
Customer: removed Property Address: xxxx Argonne AveNorfolk, VA 23505 |
This General Summary is a combined list of any and all findings that where flagged during the inspection as important. The general summary contains all the items listed in the individual summaries below.
The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
1.3 | GUTTERS, ROOF DRAINAGE SYSTEMS | |
Satisfactory, Functional, Informational notes and disclosures | ||
No gutters installed in several areas including left side and rear. The left side prohibits install of gutters because service cable is now in the way.( Picture 1 ) |
||
1.5 | VENTILATION | |
Discrepant item, Repair or Replace | ||
(1) There are no intake (soffit) vents to support roof vents. ( Picture 1 ) You must have equal make up air for adequate attic ventilation. The original gable vents are not adequate for this purpose. |
2.0 | WALL CLADDING FLASHING AND TRIM | |
Discrepant item, Repair or Replace | ||
(1) Unfinished plywood siding, No pan flashing at bottom has promoted rot. rear of garage. Siding is also separating at the seams. ( Picture 2 ) |
||
2.1 | DOORS (Exterior) | |
Discrepant item, Repair or Replace | ||
(1) Rear garage door or wall closure is missing ( Picture 1 ) |
||
(2) Right side entry door does not latch and seal properly, the keeper is missing. ( Picture 2 ) This same door also does not have a paint seal. factory powder primer finish only will not stop rusting of door skin. |
||
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
Preventative maintenance recommended | ||
(1) Evidence of poor drainage and standing water at front entry. Observed dirt and silt deposits, heavy caulk attempted at threshold, drainage groves in concrete edges.( Picture 1 ) Cannot determine if this has been cured. Inquire with current owner. |
3.0 | FOUNDATION & STRUCTURE (Report signs of abnormal or harmful water penetration into the building or signs of abnormal settlement, structural failure, wood destroying insects & fungus.) | |
Satisfactory, Functional, Informational notes and disclosures | ||
Evidence of termites detected in the attic framing and roof decking. Beware, a visual inspection can not detect termites inside concealed areas. In light of the evidence, You may want to consider a more invasive type inspection be performed by a licensed exterminator. |
||
3.6 | ROOF STRUCTURE AND ATTIC | |
Discrepant item, Repair or Replace | ||
(1) Improper workmanship of load bearing framing rafters observed in attic. (pictures 1,2,3) There are several areas where rafters where scabbed and rafter tails added. the pieces that are load bearing must have continuous load transfer to load bearing supports. |
||
(3) 2x4 16" o/c rafters do not appear to meet load requirements for the existing roof span and load. Have further evaluated and repaired as needed by a framing contractor. |
||
(4) Improper framing, rafters hang below ridge board and there are no collar ties installed. Have all areas further evaluated and repaired as needed by a framing contractor. ( Picture 8 ) |
||
3.7 | LOT& GRADING | |
Informational notes and disclosures | ||
(1) Lot is level and was not ever properly graded to provide positive drainage away from structure. Noted several drains and levies have been installed at walkways. This is typical for this age of construction. It appears that the lot drainage problem has been cured but hard to tell how it would handle a large volume of rain. |
||
(2) Side of driveway is sunken and eroded, will hold water. fill, pack, grade and seed as needed. ( Picture 1,2 ) |
4.0 | INTERIOR DRAINS, SUPPLY PIPES, FIXTURES AND VENT SYSTEMS | |
Discrepant item, Repair or Replace | ||
(1) Kitchen sink drain is not vented to atmosphere and is back venting through its own drain. ( Picture 1 )
Guest bathtub is stopped up. Guest toilet is backed up and overflowing. Guest sink basin is loose in cabinet. ( Picture 2 ) Guest bath sink drain is not vented to exterior atmosphere. Kitchen sink double drains are not plumbed properly. One drains towards and into disposal unit. Could not locate a soil vent for the clothes washing machine. |
||
(2) Note: Could not test washing machine drain without washing machine installed. |
||
(3) DISCLOSURE: This home contains antiquated style galvanized and/or iron (steel) drains. These type of drains have a limited service life of approx 30 - 50 years. They rust and constrict internally from corrosion. They can be reamed out a few times but inadvisably have to be replaced. Replacing pipes in home that are built on concrete slabs can be very expensive because it involved removal of flooring and concrete. |
||
4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
Discrepant item, Repair or Replace | ||
Adequate water pressure could not be maintained when two or more faucets are opened, especially the hot water. |
||
4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS | |
Discrepant item, Repair or Replace | ||
Water heater is notably undersized. Typical for this size house is normally 48 - 52 gallon electric.( Picture 1 )
Water heater T&P discharge pipe is missing. Should be installed for safety and discharged to the exterior of structure. Water heater drain pipe is missing from overflow pan. |
||
4.3 | Fixtures Tubs and faucets | |
Discrepant item, Repair or Replace | ||
Guest bath tub and shower has two diverters and neither one works.
Master bath toilet continues to run after flush.( Picture 1 ) Kitchen pipe on outside wall and under cabinet are not insulated from freezing.( Picture 2 ) |
||
4.4 | MAIN WATER SHUT-OFF DEVICE (Describe location) | |
Informational notes and disclosures | ||
Undetermined |
||
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | |
Informational notes and disclosures | ||
Gas fuel system has been abandoned, meter still in place. ( Picture 1 ) |
5.0 | SERVICE ENTRANCE WIRING | |
Discrepant item, Repair or Replace | ||
Service feed wire is mounted to fascia trim. These feeds are typically mounted under the soffit, out of the way of the elements, somewhat protected from ladders and equipment which can also be dangerous. This has also prohibited installation of gutters which seem much needed on this property with poor drainage. |
||
5.1 | MAIN SERVICE - Main panel, sub-panels, grounds & bonds, Capacities, Ratings, Overcurrent protection & distribution. | |
Informational notes and disclosures | ||
Could not determine or locate main ground bond to piping and earth ground. |
||
5.3 | EXTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
Garage outlet is missing cover plate.( Picture 1 ) |
||
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
(1) All kitchen wiring is on a single 110 vac, 20 amp GFCI feed. This includes all outlets, microwave, disposal, dishwasher, refrigerator. This presents numerous problems included but not limited to overloaded circuit, GFCI trip when fridge compressor is in locked rotor startup, etc. This was only detected because testing the GFCI caused shutdown of all circuits. This type of amateur workmanship does not instill confidence in other branch wiring that cannot be tested during a home inspection. This house also has a some old rag type wiring in use but most is concealed in the walls and ceilings. Have all branch wiring further evaluated and repaired as needed by a qualified electrical contractor.
|
||
(2) Fire hazard - Incandescent light fixtures used inside closets. recommend replacing with low heat fluorescent. |
||
5.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS | |
Informational notes and disclosures | ||
Service panel, located in laundry room does not appear to meet minimum clearance requirements to the left wall. have this reviewed and approved by an electrical contractor. |
6.0 | HEATING EQUIPMENT | |
Satisfactory, Functional | ||
(2) Could not find a drain pipe on the Auxiliary attic condensate drip pan. ( Picture 3 )
Main condensate drain does not contain a trap or vent. ( Picture 2 ) Thermostat wiring and power wire conduit are loose and vulnerable to damage.( Picture 4 ) |
||
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
Discrepant item, Repair or Replace | ||
Multiple areas observed where duct connections are poorly done. No mastic or adhesive is used on flanges, Duct tape is loose and failing at many of the connections and plenum seams allowing air leaks. make shift flange caps are loose and separating. have all the duct work further evaluated and repaired as needed by an HVAC contractor.
Ceiling diffuser over side entry door is loose and falling. |
7.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | |
Discrepant item, Repair or Replace | ||
No insulation installed over main part of house. ( Picture 1 )
Insulation is substandard or missing in the back areas of ceiling.( Picture 3,4 ) |
8.1 | WALLS | |
Discrepant item, Repair or Replace | ||
Less than quality plaster and paint finish workmanship. paint is uneven and inconsistent. ( Picture 2 ) most of the plaster work surface finish is inconsistent ( Picture 3 ) and corners and seams are not pointed up professionally. There are multiple shrinkage and stress cracks around doors and seams. ( Picture 7 ) ( Picture 4 )
The kitchen pantry is not taped, plaster or pointed at all and there are gaps open to the attic.( Picture 5 ) Particle board shelving is very poor as it will sag and give way over time. One closet has no shelves or rods installed. Hall closet shelf cleats are installed with finish nails and will not hold weight.( Picture 6 ) |
||
8.2 | FLOORS | |
Discrepant item, Repair or Replace, Preventative maintenance recommended | ||
Carpet in the rear of house is heavily soiled and is also coming loose in some areas.
Kitchen tile grout workmanship is poor and it does not appear to have a sealer. |
||
8.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | |
Discrepant item, Repair or Replace | ||
Cabinet over fridge location is cracked at mounts and loose on wall. ( Picture 1 )
Counter tops in kitchen and bath are substandard in designed and installation. Wood back splashes are used which will rot. ( Picture 5 ) Wood trim edge is used which will rot.( Picture 4 ) Sinks and basins are not properly secured and seal.( Picture 3 ) Counter tops are not adequately secured to base cabinets.( Picture 2 ) Many of the cabinet doors are loose and/or crooked. |
||
8.5 | DOORS (REPRESENTATIVE NUMBER) | |
Discrepant item, Repair or Replace | ||
Many of the interior doors doe not close, latch or operate as designed. Some are missing hardware, closet sliders are missing track retainers at bottom. All the doors should be gone through and reworked or repaired as needed. |
||
8.6 | WINDOWS (REPRESENTATIVE NUMBER) | |
Satisfactory, Functional | ||
(2) Right rear wooden window is not operable. ( Picture 1 ) |
||
8.7 | INTERIOR INSPECTION ACCESSIBILITY | |
Satisfactory, Functional, Informational notes and disclosures | ||
Lots of empty beer cans are hidden everywhere. ( Picture 1 )
Garage is not accessible for inspection due to construction clutter.( Picture 2 ) |
||
8.8 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
Discrepant item, Repair or Replace | ||
No Dryer vent installed. |
|
757-495-2300
|
Customer: removed Property Address: xxxx Argonne AveNorfolk, VA 23505 |
This section is a summary list of defective components, systems, or workmanship that may need repair or replacement in order to restore to intended function or to a level of what's considered "good repair".
1.0 | ROOF COVERINGS | |
Satisfactory, Functional | ||
(2) There are several punctured holes through the roof shingles where there is no roof decking in the area above the attic access hatch where the roof transitions to the back addition.( Picture 1,2 ) |
||
1.2 | FLASHING or JOINT MATERIALS | |
Satisfactory, Functional | ||
Flashing is missing at roof transition, left side towards rear. Observed exposed wood and susceptibility for water intrusion. ( Picture 1 ) |
||
1.5 | VENTILATION | |
Discrepant item, Repair or Replace | ||
(1) There are no intake (soffit) vents to support roof vents. ( Picture 1 ) You must have equal make up air for adequate attic ventilation. The original gable vents are not adequate for this purpose. |
2.0 | WALL CLADDING FLASHING AND TRIM | |
Discrepant item, Repair or Replace | ||
(1) Unfinished plywood siding, No pan flashing at bottom has promoted rot. rear of garage. Siding is also separating at the seams. ( Picture 2 ) |
||
2.1 | DOORS (Exterior) | |
Discrepant item, Repair or Replace | ||
(1) Rear garage door or wall closure is missing ( Picture 1 ) |
||
(2) Right side entry door does not latch and seal properly, the keeper is missing. ( Picture 2 ) This same door also does not have a paint seal. factory powder primer finish only will not stop rusting of door skin. |
3.6 | ROOF STRUCTURE AND ATTIC | |
Discrepant item, Repair or Replace | ||
(1) Improper workmanship of load bearing framing rafters observed in attic. (pictures 1,2,3) There are several areas where rafters where scabbed and rafter tails added. the pieces that are load bearing must have continuous load transfer to load bearing supports. |
||
(3) 2x4 16" o/c rafters do not appear to meet load requirements for the existing roof span and load. Have further evaluated and repaired as needed by a framing contractor. |
||
(4) Improper framing, rafters hang below ridge board and there are no collar ties installed. Have all areas further evaluated and repaired as needed by a framing contractor. ( Picture 8 ) |
||
3.7 | LOT& GRADING | |
Informational notes and disclosures | ||
(2) Side of driveway is sunken and eroded, will hold water. fill, pack, grade and seed as needed. ( Picture 1,2 ) |
4.0 | INTERIOR DRAINS, SUPPLY PIPES, FIXTURES AND VENT SYSTEMS | |
Discrepant item, Repair or Replace | ||
(1) Kitchen sink drain is not vented to atmosphere and is back venting through its own drain. ( Picture 1 )
Guest bathtub is stopped up. Guest toilet is backed up and overflowing. Guest sink basin is loose in cabinet. ( Picture 2 ) Guest bath sink drain is not vented to exterior atmosphere. Kitchen sink double drains are not plumbed properly. One drains towards and into disposal unit. Could not locate a soil vent for the clothes washing machine. |
||
4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
Discrepant item, Repair or Replace | ||
Adequate water pressure could not be maintained when two or more faucets are opened, especially the hot water. |
||
4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS | |
Discrepant item, Repair or Replace | ||
Water heater is notably undersized. Typical for this size house is normally 48 - 52 gallon electric.( Picture 1 )
Water heater T&P discharge pipe is missing. Should be installed for safety and discharged to the exterior of structure. Water heater drain pipe is missing from overflow pan. |
||
4.3 | Fixtures Tubs and faucets | |
Discrepant item, Repair or Replace | ||
Guest bath tub and shower has two diverters and neither one works.
Master bath toilet continues to run after flush.( Picture 1 ) Kitchen pipe on outside wall and under cabinet are not insulated from freezing.( Picture 2 ) |
5.0 | SERVICE ENTRANCE WIRING | |
Discrepant item, Repair or Replace | ||
Service feed wire is mounted to fascia trim. These feeds are typically mounted under the soffit, out of the way of the elements, somewhat protected from ladders and equipment which can also be dangerous. This has also prohibited installation of gutters which seem much needed on this property with poor drainage. |
||
5.3 | EXTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
Garage outlet is missing cover plate.( Picture 1 ) |
||
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
(1) All kitchen wiring is on a single 110 vac, 20 amp GFCI feed. This includes all outlets, microwave, disposal, dishwasher, refrigerator. This presents numerous problems included but not limited to overloaded circuit, GFCI trip when fridge compressor is in locked rotor startup, etc. This was only detected because testing the GFCI caused shutdown of all circuits. This type of amateur workmanship does not instill confidence in other branch wiring that cannot be tested during a home inspection. This house also has a some old rag type wiring in use but most is concealed in the walls and ceilings. Have all branch wiring further evaluated and repaired as needed by a qualified electrical contractor.
|
6.0 | HEATING EQUIPMENT | |
Satisfactory, Functional | ||
(2) Could not find a drain pipe on the Auxiliary attic condensate drip pan. ( Picture 3 )
Main condensate drain does not contain a trap or vent. ( Picture 2 ) Thermostat wiring and power wire conduit are loose and vulnerable to damage.( Picture 4 ) |
||
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
Discrepant item, Repair or Replace | ||
Multiple areas observed where duct connections are poorly done. No mastic or adhesive is used on flanges, Duct tape is loose and failing at many of the connections and plenum seams allowing air leaks. make shift flange caps are loose and separating. have all the duct work further evaluated and repaired as needed by an HVAC contractor.
Ceiling diffuser over side entry door is loose and falling. |
7.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | |
Discrepant item, Repair or Replace | ||
No insulation installed over main part of house. ( Picture 1 )
Insulation is substandard or missing in the back areas of ceiling.( Picture 3,4 ) |
8.1 | WALLS | |
Discrepant item, Repair or Replace | ||
Less than quality plaster and paint finish workmanship. paint is uneven and inconsistent. ( Picture 2 ) most of the plaster work surface finish is inconsistent ( Picture 3 ) and corners and seams are not pointed up professionally. There are multiple shrinkage and stress cracks around doors and seams. ( Picture 7 ) ( Picture 4 )
The kitchen pantry is not taped, plaster or pointed at all and there are gaps open to the attic.( Picture 5 ) Particle board shelving is very poor as it will sag and give way over time. One closet has no shelves or rods installed. Hall closet shelf cleats are installed with finish nails and will not hold weight.( Picture 6 ) |
||
8.2 | FLOORS | |
Discrepant item, Repair or Replace, Preventative maintenance recommended | ||
Carpet in the rear of house is heavily soiled and is also coming loose in some areas.
Kitchen tile grout workmanship is poor and it does not appear to have a sealer. |
||
8.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | |
Discrepant item, Repair or Replace | ||
Cabinet over fridge location is cracked at mounts and loose on wall. ( Picture 1 )
Counter tops in kitchen and bath are substandard in designed and installation. Wood back splashes are used which will rot. ( Picture 5 ) Wood trim edge is used which will rot.( Picture 4 ) Sinks and basins are not properly secured and seal.( Picture 3 ) Counter tops are not adequately secured to base cabinets.( Picture 2 ) Many of the cabinet doors are loose and/or crooked. |
||
8.5 | DOORS (REPRESENTATIVE NUMBER) | |
Discrepant item, Repair or Replace | ||
Many of the interior doors doe not close, latch or operate as designed. Some are missing hardware, closet sliders are missing track retainers at bottom. All the doors should be gone through and reworked or repaired as needed. |
||
8.6 | WINDOWS (REPRESENTATIVE NUMBER) | |
Satisfactory, Functional | ||
(2) Right rear wooden window is not operable. ( Picture 1 ) |
||
8.8 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
Discrepant item, Repair or Replace | ||
No Dryer vent installed. |
|
757-495-2300
|
Customer: removed Property Address: xxxx Argonne AveNorfolk, VA 23505 |
This section is a summary list of informational disclosures. These items may not be considered an obvious or repairable defect but may be an inherent problem to the home. They are listed here as they may have important consequences regarding your purchase. The items listed here are typically safety issues, environmental concerns, Antiquated systems and equipment, Building material/systems manufacturer deficiencies or recalls.
1.3 | GUTTERS, ROOF DRAINAGE SYSTEMS | |
Satisfactory, Functional, Informational notes and disclosures | ||
No gutters installed in several areas including left side and rear. The left side prohibits install of gutters because service cable is now in the way.( Picture 1 ) |
3.0 | FOUNDATION & STRUCTURE (Report signs of abnormal or harmful water penetration into the building or signs of abnormal settlement, structural failure, wood destroying insects & fungus.) | |
Satisfactory, Functional, Informational notes and disclosures | ||
Evidence of termites detected in the attic framing and roof decking. Beware, a visual inspection can not detect termites inside concealed areas. In light of the evidence, You may want to consider a more invasive type inspection be performed by a licensed exterminator. |
||
3.7 | LOT& GRADING | |
Informational notes and disclosures | ||
(1) Lot is level and was not ever properly graded to provide positive drainage away from structure. Noted several drains and levies have been installed at walkways. This is typical for this age of construction. It appears that the lot drainage problem has been cured but hard to tell how it would handle a large volume of rain. |
4.0 | INTERIOR DRAINS, SUPPLY PIPES, FIXTURES AND VENT SYSTEMS | |
Discrepant item, Repair or Replace | ||
(2) Note: Could not test washing machine drain without washing machine installed. |
||
(3) DISCLOSURE: This home contains antiquated style galvanized and/or iron (steel) drains. These type of drains have a limited service life of approx 30 - 50 years. They rust and constrict internally from corrosion. They can be reamed out a few times but inadvisably have to be replaced. Replacing pipes in home that are built on concrete slabs can be very expensive because it involved removal of flooring and concrete. |
||
4.4 | MAIN WATER SHUT-OFF DEVICE (Describe location) | |
Informational notes and disclosures | ||
Undetermined |
||
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | |
Informational notes and disclosures | ||
Gas fuel system has been abandoned, meter still in place. ( Picture 1 ) |
5.1 | MAIN SERVICE - Main panel, sub-panels, grounds & bonds, Capacities, Ratings, Overcurrent protection & distribution. | |
Informational notes and disclosures | ||
Could not determine or locate main ground bond to piping and earth ground. |
||
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
(2) Fire hazard - Incandescent light fixtures used inside closets. recommend replacing with low heat fluorescent. |
||
5.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS | |
Informational notes and disclosures | ||
Service panel, located in laundry room does not appear to meet minimum clearance requirements to the left wall. have this reviewed and approved by an electrical contractor. |
8.7 | INTERIOR INSPECTION ACCESSIBILITY | |
Satisfactory, Functional, Informational notes and disclosures | ||
Lots of empty beer cans are hidden everywhere. ( Picture 1 )
Garage is not accessible for inspection due to construction clutter.( Picture 2 ) |
|
757-495-2300
|
Customer: removed Property Address: xxxx Argonne AveNorfolk, VA 23505 |
This section is a summary of maintenance needed or preventative maintenance recommended in order to maintain a level of "good repair".
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
Preventative maintenance recommended | ||
(1) Evidence of poor drainage and standing water at front entry. Observed dirt and silt deposits, heavy caulk attempted at threshold, drainage groves in concrete edges.( Picture 1 ) Cannot determine if this has been cured. Inquire with current owner. |
8.2 | FLOORS | |
Discrepant item, Repair or Replace, Preventative maintenance recommended | ||
Carpet in the rear of house is heavily soiled and is also coming loose in some areas.
Kitchen tile grout workmanship is poor and it does not appear to have a sealer. |
|
INVOICE |
Final Analysis Home Inspections
757-495-2300 Inspected By: Dan Rogers |
Inspection Date: 2/12/2007
Report ID: barton021207 |
Customer Info: | Inspection Property: |
removed
for privacy Customer's Real Estate Professional: Bill Dorris |
xxxx Argonne Ave Norfolk, VA 23505 |
Inspection Fee:
| ||||||||||||||||
Tax $0.00 | ||||||||||||||||
Total Price $275.00 |
Payment Method:Check
Payment Status:Paid At Time Of Inspection
Note: